"ac" command

Purpose

Performs a small signal, steady state, AC analysis. Sweeps frequency.

Syntax

ac {//options// ...} //start stop stepsize// {//options// ...} 

Comments

The “ac” command does a linear analysis about an operating point. It is absolutely necessary to do an “op” analysis first on any nonlinear circuit. Not doing this is the equivalent of testing it with the power off.

Three parameters are normally needed for an AC analysis: start frequency, stop frequency and step size, in this order. If all of these are omitted, the values from the most recent AC analysis are used.

If only one frequency is specified, a single point analysis will be done.

If only a new step size is specified, the old start and stop are kept and only the step size is changed. This is indicated by a keyword: by, times, decade or octave, or a symbol: + or *.

If the start frequency is zero, the program will still do an AC analysis. The actual frequency can be considered to be the limit as the frequency approaches zero. It is, therefore, still possible to have a non-zero phase angle, but delays are not shown because they may be infinite.

The nodes to look at must have been previously selected by the print or plot command. This is different from Spice.

Options

Sweep control

start frequency Sweep start frequency.
stop frequency Sweep stop frequency.
+ stepsize Linear sweep. Add stepsize to get the next step. Same as by.
* multiplier Log sweep. Multiply by multiplier to get the next step.
by stepsize Linear sweep. Add stepsize to get the next step. Same as +.
decade steps Log sweep. Use steps steps per decade.
octave steps Log sweep. Use steps steps per octave.
times multiplier Log sweep. Multiply by multiplier to get the next step.

Input / Output

> file Send results of analysis to file.
» file Append results to file.
noplot Suppress plotting.
plot Graphic output, when plotting is normally off.
quiet Suppress console output.

Other

dtemp degrees Temperature offset, degrees C. Add this number to the temperature from the options command. This does not apply to nonlinear components, which will inherit the temperature from the operating point analysis.
temperature degrees Temperature, degrees C. This does not apply to nonlinear components, which will inherit the temperature from the operating point analysis.

Examples

ac 10m

A single point AC analysis at 10 mHz.

ac 1000 3000 100

Sweep from 1000 Hz to 3000 Hz in 100 Hz steps.

ac start=1000 stop=3000 step=100

Same as the last one.

ac 1000 3000 Octave

Sweep from 1000 Hz to 3000 Hz in octave steps. Since the sweep cannot end at 3000 Hz, in this case, the last step will really be 4000 Hz.

ac by 250

Keep the same limits as before, but use 250 Hz steps. In this case, it means to sweep from 1000 to 3000 Hz, because that it what it was the last time.

ac 5000 1000 -250

You can sweep downward, if you want. Remember that the increment would be negative.

ac 20 20k *2

Double the frequency to get the next step.

ac 20k 20 *.5

You can do a log sweep downward, too. A multiplier of less than one moves it down.

ac

Do the same AC sweep again.

ac >afile

Save the results in the file afile. The file will look just like the screen. It will have all probe points. It will be a plot, if plotting is enabled.

gnucap/manual/commands/ac.txt · Last modified: 2015/12/11 15:39 (external edit)
 
Recent changes RSS feed Donate Powered by PHP Valid XHTML 1.0 Valid CSS Run by Debian Driven by DokuWiki